Menu
Browse byCategory
Home > Video > PVC pipe > CPVC Power Cable> Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection
Mar 19, 2026
Seller Products Visit Homepage >
Bwfrp Fiberglass Braided Extruded

$79.89/ Meters View details

Building Materials Floor Tile Mesh

$2.99/ Meters View details

High Temperature Resistant Fibergl

$2.99/ Meters View details

Send your message to this supplier

Include product specification, quantity, destination port and packing needs to receive a faster and more accurate quotation.

Hengrun Group Co., Ltd.
Available today 30 times  |  Sent times  |  Remaining times
Thickness 5-20mm
Usage Environmental Protection, Industral, Infrastructure/Transportation Energy/Industry
Product Categories FRP Pipe
Molding Method Pultrusion
Material Fiberglass
Fiber Type GFRP
Type Epoxy FRP
Structure Multi-Layer Composite Filament Winding
Temperature Range -40°c to 120°c
Corrosion Resistance Resistant to Acids, Alkalis, Salt Spray, Organic S
Strength Ring Stiffness ≥32 kN/M² (Sn8 Class)
Weight Density 1.6-2.0 G/Cm³, Lighter Than Steel Pip
Friction Coefficient Smooth Inner Wall, Friction Coefficient ≤0.0084
Flame Retardancy Oxygen Index ≥28 (Class B1)
Insulation Volume Resistivity ≥1×10¹³
UV Resistance Contains Anti-Aging Agents, Outdoor Service Life
Connection Methods Connection Methods
Length Standard 6m/9m/12m, Customizable
Diameter Range DN50 to DN600 mm
Pressure Rating 0.6 MPa to 2.5 MPa
Flexibility Minimum Bending Radius ≥18× Pipe Diameter
Water Tightness Leak-Proof (0.1 MPa/24h)
Transport Package Bale Packaging
Specification Customizable
Trademark Hebei Hengrun
Origin Hebei China

Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection

Fiberglass cable protection conduit (FRP cable conduit) is made of high-performance composite materials, which have four core advantages: corrosion resistance, high strength, insulation flame retardancy, and lightweight convenience. Its service life is up to 50 years, which can resist acid, alkali, salt spray and moisture erosion. The ring stiffness is ≥ 12.5kN/m ², the compressive performance is excellent, the oxygen index is ≥ 28, and the flame retardant level reaches UL94 V-0 standard, ensuring the safe operation of the cable. The product diameter covers DN50-DN300, with a pressure rating of 0.6-2.5MPa, weighing only 1/4 of steel pipes, and increasing installation efficiency by more than 60%. It is widely used in fields such as power, communication (such as 5G optical cables), and transportation (subways, highways), and is a high-quality choice that balances performance and cost-effectiveness.

Specification

Nominal inner diameter (mm)

Wall thickness (mm)

Length (mm)

Ring stiffness (SN grade)

Weight (kg/m)

50

5

4000

SN5000

1.8

70

5

4000

SN5000

2.3

80

5

6000

SN5000

2.7

100

5

4000

SN5000

3.3

100

8

4000

SN5000

5.4

125

5

4000

SN5000

3.8

150

3

4000

SN25

2.8

150

5

6000

SN25

4.8

150

8

4000

SN80

7.6

150

10

4000

SN80

9.5

175

4.5

6000

SN28

7.9

175

10

4000

SN80

11.0

200

10

4000

SN80

12.4

200

12

4000

SN80

15.0

Produce

Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection

1. Material preparation
Mix resin, curing agent, and glass fiber (short cut felt/continuous yarn).
2. Forming
Immersed fiber spiral winding mold (CNC controlled angle and tension)
3. Curing
Heat (60-80 ℃) or cure at room temperature for 2-8 hours.
4. Demoulding and trimming
Cut and polish the edges after demolding, and apply a protective layer if necessary.
5. Quality inspection
Test the stiffness and hardness of the testing ring, and package it after passing the inspection (4m/6m standard length).

Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection

 

High strength and lightweight: With a density of only 1/4 of steel pipes, it can be directly buried under the roadway without the need for a concrete protective layer, resulting in high construction efficiency.
Strong corrosion resistance: can resist acid, alkali, salt and organic solvent erosion, with an inner lining resin content of 70% -95% and a lifespan of over 50 years

Excellent electrical insulation performance: non-magnetic material, no eddy current loss, suitable for single core cable laying, ensuring safe cable operation.
Wide temperature resistance range: It can be used for a long time from -50 ℃ to 130 ℃, with frost resistance, heat resistance, and no deformation.
Smooth inner wall and low resistance: It is not easy to scratch the cable when threading, with low fluid resistance and reduced energy consumption

Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection

Application


Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection

1. Energy and electricity: urban power grid renovation, new energy power stations (photovoltaic/wind power), high-voltage transmission projects.
2. Transportation infrastructure: high-speed rail/subway tunnels, highways, and cross water projects (bridges/submarine cables).
3. Communication municipal: 5G optical cable protection, municipal power pipeline network, airport underground cables.
4. Special environment: Corrosive or complex geological areas such as chemical zones, saline alkali land, and soft soil geology.
5. Industrial facilities: sewage treatment plants, underground pipelines in densely populated areas.

Packaging & Shipping

Bwfrp Fiberglass Braided Extruded Pipe for Municipal Power Line Protection